project-img
project-img
project-img
 
 
 

Dilitcen 22 R Centrifuge

The largest of our benchtop machines, with a capacity of up to 4 litres and an ergonomic design that enables easy loading of the rotor, as well as traceability of the positioning of the samples so as to balance the load and for easy identification. It has a wide range of accessories with capacity for four 1.000 ml. bottles, microplates, microtubes and a large number of positions for the most commonly used 15 ml. conical, 50 ml. conical, 15 ml., 10 ml. and 5 ml. tubes for clinical as well as biotechnology applications. Its colour TFT touch screen offers performance that enables, in addition to controlling the equipment by operational parameters, the possibility of exporting data for analysis and timer programmed operation. The autonomy provided by this equipment facilitates the automation of work cycles and modes. This also ensures traceability of the process, not leaving any parameter uncontrolled and maintaining the process at all times. It has a refrigeration system that enables it to maintain the minimum temperature of the chamber below 4°C regardless of the type of rotor and the speed selected.

  • Shows RPM and RCF, time, temperature, acceleration/deceleration values (PCBS) and unbalance location system (ULS).
  • Speed programming in 10 RPM/10 xg steps.
  • Real RCF values on screen based on accessories configuration.
  • Count up/down from “0” or at “set RPM/RCF” for reproducible tests.
  • PCBS: Progressive controlled acceleration and braking system up to 175 selectable ramps that prevents sample homogenization after separation.
  • ULS: Unbalance location system indicating on the screen the number of the bucket which produces the unbalance switch off.
  • Start delay: To program the time at which the cycle is to begin.
  • Linked program: Permits the linking of up to 8 consecutive programmes without the need of user intervention.
  • 40 programmable memories, with protection under password.
  • Several acoustic and visual messages showing the situation of the device to the user.
  • Microprocessor controlled. Connectivity.
  • Induction motor maintenance free (brushless).
  • Rotors and adapters list in memory.
  • Noise level: below 60 dB.
  • Start, stop, open lid and short spin with adjustable speed buttons.
  • Possibility to block or modify the speed during the cycle
  • Last values remain in memory.
  • Automatic rotor recognition. Over-speed protection
  • Biocen 22 R, Bioprocen 22 R, Digicen 22 R, Consul 22 and Digtor 22
  • Unicen 21 and Digicen 22
  • Consul 22 R, Digtor 22 R and Dilitcen 22 R - to place under table
  • Consul 22 R, Digtor 22 R and Dilitcen 22 R